Extract filter size: - mmSupply filter size: 350x250x40 mmFilter class (EN779): G4Filter quantity in a set: 1 filterProtection level
Filter protection level indicates efficiency in blocking particles or contaminants, varying by standard and application.
BasicGeneral dust and particle filtration
Extract filter size: 475x180x50 mmSupply filter size: 475x180x50 mmFilter class (EN779): G4+F7Filter quantity in a set: 2 filtersProtection levelFilter protection level indicates efficiency in blocking particles or contaminants, varying by standard and application.
BasicGeneral dust and particle filtration
Pollen and moldCaptures pollen, mold spores, and other allergens
Smog and bacteriaProtects against allergens and urban pollution
Extract filter size: 174x168x45 mmSupply filter size: 174x168x45 mmFilter class (EN779): M5+F7Filter quantity in a set: 2 filtersProtection levelFilter protection level indicates efficiency in blocking particles or contaminants, varying by standard and application.
BasicGeneral dust and particle filtration
Pollen and moldCaptures pollen, mold spores, and other allergens
Smog and bacteriaProtects against allergens and urban pollution
Extract filter size: 174x168x45 mmSupply filter size: 174x168x45 mmFilter class (EN779): M5+M5Filter quantity in a set: 2 filtersProtection levelFilter protection level indicates efficiency in blocking particles or contaminants, varying by standard and application.
BasicGeneral dust and particle filtration
Pollen and moldCaptures pollen, mold spores, and other allergens
Extract filter size: 275x187x20 mmSupply filter size: 275x187x20 mmFilter class (EN779): G4+G4Filter quantity in a set: 2 filtersProtection levelFilter protection level indicates efficiency in blocking particles or contaminants, varying by standard and application.
BasicGeneral dust and particle filtration
Extract filter size: 275x187x20 mmSupply filter size: 275x187x20 mmFilter class (EN779): G4+F7Filter quantity in a set: 2 filtersProtection levelFilter protection level indicates efficiency in blocking particles or contaminants, varying by standard and application.
BasicGeneral dust and particle filtration
Pollen and moldCaptures pollen, mold spores, and other allergens
Smog and bacteriaProtects against allergens and urban pollution
Extract filter size: 275x187x20 mmSupply filter size: 275x187x20 mmFilter class (EN779): G4+F7Filter quantity in a set: 2 filtersProtection levelFilter protection level indicates efficiency in blocking particles or contaminants, varying by standard and application.
BasicGeneral dust and particle filtration
Pollen and moldCaptures pollen, mold spores, and other allergens
Smog and bacteriaProtects against allergens and urban pollution
Extract filter size: 475x180x50 mmSupply filter size: 475x180x50 mmFilter class (EN779): G4+G4Filter quantity in a set: 2 filtersProtection levelFilter protection level indicates efficiency in blocking particles or contaminants, varying by standard and application.
BasicGeneral dust and particle filtration
Extract filter size: 475x180x50 mmSupply filter size: 475x180x50 mmFilter class (EN779): G4+F7Filter quantity in a set: 2 filtersProtection levelFilter protection level indicates efficiency in blocking particles or contaminants, varying by standard and application.
BasicGeneral dust and particle filtration
Pollen and moldCaptures pollen, mold spores, and other allergens
Smog and bacteriaProtects against allergens and urban pollution
Extract filter size: 475x180x50 mmSupply filter size: 475x180x50 mmFilter class (EN779): G4+F7Filter quantity in a set: 2 filtersProtection levelFilter protection level indicates efficiency in blocking particles or contaminants, varying by standard and application.
BasicGeneral dust and particle filtration
Pollen and moldCaptures pollen, mold spores, and other allergens
Smog and bacteriaProtects against allergens and urban pollution
Extract filter size: 174x168x45 mmSupply filter size: 174x168x45 mmFilter class (EN779): M5+M5Filter quantity in a set: 2 filtersProtection levelFilter protection level indicates efficiency in blocking particles or contaminants, varying by standard and application.
BasicGeneral dust and particle filtration
Pollen and moldCaptures pollen, mold spores, and other allergens
Extract filter size: 174x168x45 mmSupply filter size: 174x168x45 mmFilter class (EN779): M5+F7Filter quantity in a set: 2 filtersProtection levelFilter protection level indicates efficiency in blocking particles or contaminants, varying by standard and application.
BasicGeneral dust and particle filtration
Pollen and moldCaptures pollen, mold spores, and other allergens
Smog and bacteriaProtects against allergens and urban pollution
1-12 of 12Shop Paul MVHR filters for Focus, Climos and Novus ventilation units, plus replacement filters for the ISO Defroster DN 160. Choose from original and house brand options, with G4, M5 and F7 grades available across the range. Start with your exact unit model, then compare the filter specification and set contents.
Our Paul heat recovery filters cover routine replacement on the incoming and extract air sides of compatible systems. Whether you are replacing a familiar set or considering finer supply air filtration, use the model links below to narrow your choice before ordering.
Find replacement filters for your Paul MVHR model
Paul filters are model specific. A matching brand name or filter grade alone does not confirm that a replacement will fit. Check the full model on your unit’s identification label or in its manual, including any letters or numbers after the series name.
- Paul Focus filters cover the Focus 200 range. Compare the listed G4+G4 and G4+F7 options against your unit’s requirements.
- Paul Climos filters include sets for Climos (F) 200 units, with M5+M5 and M5+F7 combinations listed.
- Paul Novus 300 and 450 filters are grouped together for convenient comparison. Open the individual product to confirm compatibility and the supplied filter combination.
- The Paul ISO Defroster DN 160 G4 replacement filter serves the specified filter box accessory. This is a replacement filter, not a complete Paul ISO Filterbox or ventilation unit.
If the label is difficult to read, keep a photograph of the unit and the old filter’s markings. Dimensions can help confirm your selection, but check them alongside the model and product code.
Original and compatible Paul filters
Original Paul filters
Choose products labelled Original when you want genuine Paul filters. Check the model, filter classes and manufacturer’s part number where provided. Original sets are available for selected units; the choices shown depend on the model.
House brand replacement filters
Our House brand products are EU-made alternative replacement filters listed for specified Paul units. These compatible Paul filters offer another purchasing option when you are comparing the cost of regular maintenance. They are clearly labelled separately from original products.
Compare equivalent sets carefully: the same dimensions do not guarantee the same filtration performance. Look at the stated ISO 16890 rating, filter positions and quantity. Choose the option that meets your system’s requirements and budget.
For a useful price comparison, check what each pack contains. A two-filter maintenance set and a single accessory filter serve different purposes. Compare sets for the same model and filtration requirement, then review the current product price and delivery information before checkout.
Choose the right Paul filter grade
Filter grade describes filtration performance, while the model and dimensions determine fit. Choose a grade supported by your unit. The available combinations vary across the Paul range, so there is no single set for every installation.
G4 filters for coarse dust
G4 filters capture larger airborne material such as coarse dust and lint. They are a practical option where the unit specification calls for this grade. Selected Paul sets pair a G4 extract filter with either a G4 or F7 supply filter.
M5 filters for selected Climos sets
M5 options appear in the Climos (F) 200 range. Compare M5+M5 and M5+F7 sets according to the filtration required on each air path. For more detail about particle capture, use the individual product’s tested rating rather than assuming every M5 filter performs identically.
F7 filters for finer supply air filtration
F7 supply filters are worth comparing when you want finer particle filtration, including pollen filtration, and your Paul model supports them. Suitable sets combine the F7 supply filter with the specified extract filter. Retain the combination recommended for your installation when replacing both.
For pollen concerns, focus your comparison on the incoming air filter and its documented performance. A particle filter does not remove every type of air pollution, and an F7 label alone does not establish performance against gases or odours.
Understanding ISO 16890 ratings
G4, M5 and F7 are labels from the older EN 779 standard. ISO 16890 uses classifications including ISO Coarse, ePM10, ePM2.5 and ePM1, alongside a percentage describing tested filtration performance. The two standards use different test methods, so there is no exact universal conversion.
Read the ISO classification for the specific filter you are buying. For example, an ePM1 percentage describes performance against the standard’s PM1 particle fraction; it is not a promise to remove that percentage of every airborne pollutant in your home.
Supply and extract filters have different jobs
The supply air filter treats incoming outdoor air before it reaches the living spaces. The extract air filter captures particles in air drawn from the home before that air passes through the unit. Both contribute to protecting the ventilation equipment.
A set labelled G4+F7 or M5+F7 contains different grades for these air paths. Check the product’s supply and extract details to identify each one. Follow the unit instructions and any airflow arrows when fitting the filters; do not assume the two positions are interchangeable.
Check these details before you order
Use this short checklist to choose your Paul replacement filters:
- Exact model: match the full unit name to the product’s compatibility list.
- Filter dimensions: compare length, width and depth in millimetres.
- Grade and air path: confirm the required supply and extract specifications.
- Set contents: check whether the item contains one filter or a pair.
- Product type: select Original or House brand deliberately.
Once you have confirmed the correct replacement, save its product code for your next order. A spare set can make planned maintenance easier; keep unused filters clean, dry and protected in their packaging.
Ordering for several ventilation units? Check each unit separately and label spare packs with their intended location and model. This helps keep the right supply and extract filters together and makes the next scheduled change easier to organise.
Paul MVHR filter replacement and maintenance
Follow the replacement schedule in the manual for your exact unit and check the filters regularly. Dust levels, nearby building work and operating conditions can affect how quickly they become dirty. Replace damaged or heavily soiled filters promptly.
Keep a simple record of installation dates and what you find at each inspection. If a filter becomes heavily loaded before the scheduled change, arrange an earlier replacement and review the inspection frequency. A calendar reminder helps you keep maintenance on track.
For example, the Paul NOVUS (F) 300/450 operating manual, version 2.0 dated May 2015, specifies changing both unit filters every 90 days in its customer maintenance checklist. Use the manual applicable to your own unit rather than treating a general three to six month range as suitable for every model.
For changing instructions, open your chosen product and select How to change. The Focus 200 G4+F7 product page, for example, links to a model-specific replacement manual. Follow its shutdown, fitting and restart instructions, then reset the filter reminder as directed.
Frequently asked questions about Paul filters
Which filter fits my Paul MVHR unit
Match the exact unit model, filter size and required grade to the product specification. Start with the Focus, Climos or Novus links above. If the identification label and old filter markings disagree, confirm the specification before placing an order.
Can I wash my Paul MVHR filters
Do not wash a replacement filter unless its own documentation explicitly says it is washable. Cleaning instructions for the heat exchanger or extract valve prefilters do not automatically apply to the main unit filters. Replace disposable filters when due.
Do Paul Novus and Focus use the same filters
No. The listed Focus 200 and Novus 300/450 sets have different dimensions. Buy the set specified for your model, even if both products carry the same G4 or F7 grade.
Where can I get help choosing a filter set
Contact Filter Express with the model name, filter dimensions and any part number you can find. A clear photo of the unit label can help explain what you need.
Choose your Paul filter set
Browse the matching model range, compare original and house brand options, and check the specification before adding your set to the basket. Shopping for another ventilation brand as well? Explore our full range of MVHR replacement filters.
Customer Reviews
Need Help? Start Here.
We’ve gathered answers to the most common questions about our products and services. If you can’t find an answer here, please contact us directly.
Since Passive House buildings rely entirely on MVHR for fresh air, is an H13 HEPA upgrade worth considering for a Paul unit?


Because Passive House buildings are airtight and depend on the MVHR system for essentially all fresh air exchange, filtration quality matters more than in a leakier property — an H13 HEPA-grade supply filter can meaningfully reduce fine particulate and allergen levels indoors. It's a common upgrade for allergy-sensitive households, though it's worth checking your Paul model's fan capacity first.
Do Paul Novus and Focus models use the same filter housing size, or does it vary by airflow capacity?


Filter housing size varies by airflow capacity within both the Novus and Focus series, so two units sharing a series name can still take different filter dimensions. The full alphanumeric model code — not just ‘Novus’ or ‘Focus’ — is what confirms the exact size for your unit.
How do I identify my exact Paul model (e.g. Novus, Focus)?


Two pieces of information on the unit's front panel confirm your exact Paul model:
- The series name, such as Novus or Focus
- The longer alphanumeric model code, which specifies airflow capacity
Both help match you to the correct filter set, especially where multiple airflow variants share a series name.
What filter class is recommended for Paul units?


Paul units typically use an M5 filter for general dust and an F7 (ePM1) filter for fine particle and pollen filtration on the supply side, matching the airtight, well-sealed construction typical of Passive House buildings. Because these homes rely heavily on the MVHR system for all fresh air, keeping filters current is especially important for indoor air quality.
Why is Paul associated with Passive House ventilation specifically?


Paul Wärmerückgewinnung is a German pioneer of ventilation systems designed for Passive House and low-energy buildings, with several unit series built around very high heat-recovery efficiency. Filter selection follows the same M5/F7 logic as other MVHR brands, matched to your specific Paul model.